We use cookies to ensure you get the best experience on our website. By using this site, you agree to these cookies being set. To learn more, read our privacy policy.
View policyOk

Joseph P. Teasdale State Office Building Parking Structure

Joseph P. Teasdale State Office Building Parking Structure

a photo of the top of a parking structure receiving repairs
Raytown, Missouri, United States
Preserving an aging post-tensioned parking structure through adaptive structural rehabilitation and galvanic corrosion protection.
Owner: State of Missouri
Consultant: Structural Engineering Associates, Inc.
Contractor: John Rohrer Contracting Co., Inc.
Completed: 2025

Originally constructed in 1973, the Joseph P. Teasdale State Office Building's two-level parking structure in Raytown, Missouri, required extensive rehabilitation after decades of service. What began as a relatively straightforward concrete repair project evolved into a complex structural preservation effort as previously undocumented post-tensioning systems and significant structural deficiencies were uncovered.

Through collaboration and an adaptable rehabilitation approach, the project team successfully preserved the existing facility and extended its service life, earning the 2026 ICRI Award of Excellence in the Parking Structures category.

The Problem

Initial assessments identified areas of deteriorated concrete, but the full extent of the structure's deficiencies became apparent only after demolition began. Previously undocumented buttonhead anchorages were discovered just inches below the slab surface, along with multiple post-tensioning systems, congested reinforcement, and broken post-tensioning strands.

Further investigation revealed the complete failure of the buttonhead anchorage system supporting a critical center beam, significantly expanding the scope of the rehabilitation. The project team faced the challenge of addressing these unexpected structural deficiencies while preserving as much of the existing structure as possible. Limited access, complex reinforcement arrangements, and incomplete original documentation added further challenges to the repair process.

The Solution

The project team developed an adaptive rehabilitation strategy combining extensive structural repairs, post-tensioning rehabilitation, and long-term galvanic corrosion protection. Structural improvements included repairs to existing post-tensioning systems, new anchorage assemblies, and additional foundation and steel support elements to restore the structural load path.

To help protect the remaining post-tensioning systems and reinforcing steel, more than 1,600 galvanic anodes were incorporated into the rehabilitation, including Vector's Galvashield® CC and Galvashield® XP2 products.

Galvanic anodes were installed near vulnerable post-tensioning components to mitigate corrosion, while additional anodes were incorporated into conventional concrete repairs to reduce the risk of new corrosion developing adjacent to repaired areas.

As construction progressed, installation methods were continually adapted to accommodate unexpected site conditions. These adjustments included alternative drilling locations, specialized mounting arrangements, and electrical connection methods suited to the structure's original post-tensioning systems.

The Result

The completed rehabilitation successfully preserved the existing parking structure, avoiding the significant cost and disruption associated with demolition and replacement. The project included approximately 25,000 square feet of elevated deck replacement, extensive beam and post-tensioning repairs, and a comprehensive corrosion protection system.

Designed to provide a minimum service-life extension of 20 years, the rehabilitation addressed critical structural deficiencies while supporting the long-term durability of the remaining concrete and post-tensioning systems.

Preserving the existing structure also delivered substantial environmental benefits. Compared with replacement, the project was estimated to avoid more than 1,000 tons of carbon dioxide emissions and divert approximately 3,746 tons of demolition waste from landfill.

The project demonstrates how adaptable engineering, collaboration, and effective corrosion mitigation can extend the life of aging infrastructure, even when significant unforeseen conditions arise during rehabilitation.