Wasserturm Genthin

Wasserturm Genthin

a photo of Wasserturm Genthin being repaired
Genthin, Germany
Protecting a historic German water tower through targeted corrosion protection.
Owner: Stadt Genthin
Consultant: Prof. Dr.-Ing. Andrei Walther
Contractor: Ed. Züblin AG Direktion Bauwerkserhaltung
Completed: 2026

After approximately 80 years of service, the Genthin water tower required repairs to address advanced reinforcement corrosion along the edges of its vertical concrete ribs. As part of the rehabilitation, a targeted corrosion protection system was incorporated to help protect the repaired structure and extend the service life of these critical elements.

The Problem

Areas of advanced corrosion had developed along the reinforced concrete edges of the tower’s vertical ribs. Although damaged concrete could be repaired, there was a risk that corrosion could continue or develop in the reinforcement adjacent to the repaired areas due to chloride exposure, moisture ingress, and electrochemical potential differences between repaired and unrepaired concrete.

For this historic structure, the rehabilitation strategy needed to address these vulnerable areas while limiting intervention to locations where additional corrosion protection was technically required.

exposed rebar on a concrete structure shows corrosion
Galvashield Fusion T2 anode installed in concrete

The Solution

Galvashield® Fusion® T2 anodes were installed in pre-drilled holes in structurally sound concrete and electrically connected to the existing reinforcement.

The system was selected to provide two stages of corrosion protection. An initial electrochemical treatment helps reduce active corrosion and promote repassivation of the reinforcing steel. This is followed by long-term galvanic protection designed to reduce the risk of future corrosion in the protected areas.

By targeting vulnerable reinforcement around the repair areas, the system complemented the concrete repairs without requiring extensive additional removal of otherwise sound concrete.

The Result

The completed rehabilitation provides targeted corrosion protection to vulnerable reinforcement along the water tower’s repaired concrete ribs. Incorporating Galvashield® Fusion® T2 into the repair strategy helps reduce the risk of ongoing and adjacent corrosion, improving the durability of the repairs and extending the service life of critical elements of the historic structure.

The targeted approach also limits corrosion protection measures to areas where they are technically required, helping reduce the potential need for future repair interventions and their associated costs.