Vector Corrosion Technologies - News


Vector Introduces Galvashield® XP+, 2nd Generation Discrete Galvanic Anode
February 04

Vector Corrosion Technologies, a leading supplier of products and services for corrosion mitigation in concrete and masonry structures, is pleased to announce the launch of a new embedded galvanic anode at World of Concrete 2004 in Orlando, FL.

Vector® Galvashield® XP+ is a second-generation puck-shaped discrete galvanic anode that builds upon the success of the original Vector Galvashield XP technology introduced in North America in the late 1990's. Since its introduction, Galvashield XP has set the standard for discrete galvanic anodes used for corrosion prevention in concrete rehabilitation.

Vector Galvashield XP+ is used to provide localized protection at the interface between new concrete and chloride-contaminated concrete where accelerated corrosion activity is typically experienced. The product can be used to protect conventionally reinforced, prestressed, and post-tensioned structures. Specific applications include patching of spalled concrete in structures subject to corrosive conditions; balcony replacements, bridge widening and of post-tensioned anchorage repair.

The new Galvashield XP+ discrete anode utilizes an innovative zinc core design to provide approximately 2 times the current output depending on the environment. This new level of performance now allows discrete galvanic anodes to be used for both corrosion prevention and corrosion control applications where a higher level of current is required to mitigate active corrosion.

  • Corrosion Prevention ­ Proper repair is completed per ICRI guidelines whereas the area of the patch is expanded until clean steel is encountered. The anode is designed to prevent the initiation of new corrosion in adjacent areas where there currently is no corrosion activity. Galvashield XP and Galvashield XP+ are both designed for this application.

  • Corrosion Control ­ The assumption is that there may be active corrosion at sites around the anode. For example, the patch is not extended until clean steel encountered, some slab replacement projects, bridge widening, etc. The objective is to reduce on-going corrosion activity. Galvashield XP+ is designed to be used for this application.

    For additional information on corrosion prevention, corrosion control, and cathodic protection, please refer to the technical document Corrosion Mitigation Strategies which provides a detailed description of these different approaches for corrosion protection.


  • ARCHIVE

  • MTO Installs Galvanic Bridge Deck Overlay
     
  • Vector Introduces Galvanode™ ASZ+ Activated Arc Spray Zinc
     
  • Norcure® ECE and Galvashield XP protects I-480, as Published in Bridge Builder
     
  • Corrosion Management Systems for Concrete, as Published in Concrete International
     
  • FDR Drive Rehabilitation Selected New York Construction Project of the Year
     
  • Reagan National Airport Selects Norcure® Re-alkalization and Chloride Extraction
     
  • I-480 Bridge Repair Project Receives ICRI Award
     
  • Vector Corrosion Technologies Receives Sustainable Development Award
     

    ©2005 Vector Corrosion Technologies. All rights reserved.
    No part of this web site may be reproduced without the express written consent of Vector Corrosion Technologies.

    To report technical problems when attempting to use this website please contact the webmaster.