Galvanic protection systems utilize dissimilar metals to provide protection to embedded reinforcing steel. When two metals are coupled together in an electrolyte, the metal with the higher potential for corrosion (more electronegative) will corrode in preference to the more noble metal. In the case of concrete, zinc is used to provide galvanic protection to the steel. This type of system does not require on-going monitoring and is suitable for conventionally reinforced and prestressed/post-tensioned concrete. The following additional information is available: Galvashield MA
Downloadable files -
|
Vector Galvashield® MA - Vector Galvashield MA activated reinforced zinc mesh overlay system is used to provide galvanic corrosion protection to reinforced concrete structures that are subject to corrosive conditions. The system is based upon the installation of a reinforced zinc mesh anode onto the surface of the concrete structure to be protected. The anode system is electrically connected to the steel reinforcement and then overlayed with an activated mortar. When the system installation is complete, the thin overlay system provides long term corrosion protection. Applications:
Features and Benefits
*As with all galvanic protection systems, service life is dependent upon a number of factors including reinforcing steel density, concrete conductivity, chloride concentration, humidity and anode selection. |